What are the common failures of the can filling machine?These problems have become a more important common sense of the use of can filling machine. Here we will understand the causes and elimination methods of the failure of can filling machine.
1.After starting up, the LCD screen of the display controller has no display.
Cause of failure: whether the power socket is powered;Whether the power plug is off;A loose or blown fuse.
Troubleshooting: re-plug the plug;Reinstall or replace the fuse;Note that fuses must be selected in accordance with the specifications.
Note: Check and determine what caused the blown fuse.
2.After starting up, the display screen displays correctly and indicates that it is running, but the pump wheel does not turn.
Cause of failure: the inner roller of the pump head is stuck;No bottle stop line is not connected or the battery is wrong;Drive circuit board is broken.
Troubleshooting: according to the requirements of the pump head installed;Connect the non-bottle stop line and make the level correct;Check the problem of the circuit board.
Note: The maintenance of circuit board shall be done by the supplier or the company.
3, The pump wheel rotation, but can not transport liquid.
Fault cause: the rubber hose is not pressed in place;The hose is broken and leaking fluid.
Troubleshooting: adjusting the regulating screw on the cover of the pump head;Replace with a new hose.
4.When working, the hose slides to one side with the roller.
Cause of failure: hose not properly secured
Troubleshooting: connect the hose with a tee and hang it on the fixing screw or clamp it with the pipe.